Infrared Imaging, commonly referred to as IR, is a very useful tool for anyone practicing building science. It provides visual images that offer clues to what is happening, temperature wise, in the wall (or floor, ceiling, roof...).
Wait, that last sentence is rather, well, limiting. Doesn't IR see through walls?
No, IR isn't magic. It's simply making a best guess about the temperatures on the surface of the walls based on a lot of assumptions. The operator of the equipment has supplied some of those assumptions as has the manufacturer of the imager. The manufacturer made his assumptions based on solid physics and years of testing. The operator is making his assumptions based on what he remembers from his training and how he is interpreting the conditions of the objects he's imaging. This can be a weak link, and it's where most bad IR interpretation starts to go wrong.
That's the other thing. IR doesn't tell you anything, it gives you information that you need to interpret. The operator needs to understand the workings of the system that's being imaged or the images make no sense. I work with buildings and I'm comfortable interpreting IR images of buildings. Ask me to evaluate an image of a horse and you might as well flip a coin, I'd be way in over my head on that.
Still, IR is a powerful tool to have. Because of the relative speed of acquiring information and because it can present that information graphically it makes diagnosing problems quicker and better. Homeowners get a better understanding as well. Seeing the effect of missing insulation really brings the point home quicker than the proverbial thousand words of explanation.
Let's take a look at a few images. The first one is simple. We're looking at a ceiling on the top floor of a building. The attic above is cooler than the room and the sun hasn't warmed it up yet. This attic had no access so I had to base my interpretation solely on this image. Fortunately when the contractor made an access to insulate the area properly I was proven correct.
The fiberglass insulation is in batt form. One end of a batt is being held up by the can light in the picture and the cold air in the attic is getting under it to the drywall ceiling. This is a classic situation and all too common. But this had been in place for 12 years and until I came in with a thermal imager no one knew about it. If you read my post on gaps in insulation you know how bad this can be.
One of the most useful things you can do with IR is find air leaks. With a reasonable temperature difference between inside and out I can use the blower door to create airflow. Once the door has run a few minutes you can get images like the one below. The cold air flowing from the attic creates the cold (blue) streaks on the warmer surfaces. Not only are these powerful for illustrating the effect, an air sealing contractor can use this as a guide to what needs to be done.
Important note: Ask anyone offering air sealing if they use a blower door and IR to find leaks and confirm results. Working without these tools is like tying your hands behind your back.
Once in a while you run into airflow strong enough that you can see it without a blower door. Every building science professional I have shown this image to assumes I had the blower door running on a cold day. The temperature difference was 20 - 25 degrees between in and out. My blower door was still in the van, so what happened?
I was in the lowest level of a former barn converted to child care. The building was a tall 4 stories and a really good example of the stack effect in a building that is leaky at both the top and the bottom. Think what the airflow would be like on a really cold day!
Sometimes unexpected patterns show up. Below is a small section of wall in a half basement. At the very top right is the edge of the board that caps the wall that is against the concrete wall. (BTW, this should not be done the way it was, that deserves a separate post.) The lower left is just a chair that intruded into the image. The orange-ish section on the right is mostly undisturbed fiberglass insulation under drywall. The center area, with those dark splotches are tunnels and nesting cavities created by mice. We confirmed this by removing the drywall (wearing protective masks and clothing) and cleaning out the mess and damaged insulation. Excluding vermin is really important in buildings both for health reasons and because they can cause damage to insulation and structure.
All of the above information was inferred from the temperature of the surfaces I looked at. With the IR and knowledge and experience with buildings I got the right answers. Ask your prospective energy auditor how much experience they have with buildings. If they were selling cars last month will they be able to adequately interpret the information they gather? Having the tools doesn't give you the skills and knowledge to use them.
Sometimes you can have a little fun with IR. I worked on several child care centers over the past few years. It was the most fun I've had on any project I've done. IR is not ideal for portraits but I got a lot of requests from the kids (Take my picture! Me too! You took her picture. Take mine). This little girl had just been playing outside and she was warming her cold hands on her forehead.
I'm told that IR is commonly being used in some countries as a medical diagnostic tool. The only interpretation I was able to make was that she had been having fun.
When you get an energy audit don't forget to have your picture taken as part of the process!
The glamor and excitement of building science. Sometimes a little psychology too.
See my website at: Building Diagnostics Follow me on Twitter @buildinggeek
What happens here?
What happens here?
Buildings, energy, energy policy, indoor air quality, problems, triumphs, successes, failures and the people and processes that affect them.
Feel free to draw any tangential connection you think appropriate.
I love spirited and enthusiastic exchanges, but please maintain the decorum.
Showing posts with label Leaks. Show all posts
Showing posts with label Leaks. Show all posts
Tuesday, April 9, 2013
Thursday, March 14, 2013
Old houses are like old people. You can learn a lot from them if you take the time and respect them.
One of my indulgences is taking time to look at a detail in an old house and trying to get into the head of the craftsman who made it. I can't say that every try is successful, but when I do figure it out there have been some great "Aha!" moments. More than a few times it's taken years and some other discoveries to see what was going on.
Sometimes it's a structural choice; how were two pieces of wood joined, why was that support here and not there. It could be material choice or why did that window go into THAT corner. Sometimes there's a really good, smart reason, other times it's tough to figure and there are some clear mistakes. These are lessons that are sitting right there waiting to be learned and many of them are still applicable today.
One important thing about successful (surviving) old buildings is that they could dry out if they got wet. Quickly too. And that's the important part, if wood stays wet it rots. If it dries quickly it's fairly forgiving of some periodic wetting. If you let it get too wet too often your building won't survive for future generations to see how stupid you were.
How did they dry and are there lessons about that for today? They dried because of lot's of air and energy flow and materials that don't trap moisture. No insulation and free air movement in wall cavities are a recipe for drying. Interior horsehair plaster dries very rapidly which also helped keep the walls dry. Of course in the 18th & 19th centuries showers and hot tubs were in short supply and indoor swimming pools were even rarer. So buildings had lower moisture loads to deal with and had good drying potential. That's a good way to make a building that will last.
We have become more regular in our hygiene and with high energy costs we want insulation in our walls and ceilings. This puts us in a bit of a bind because we just messed up our building longevity strategy. What to do? Let's go back to our original building and see what else we need to change. Well, if the walls won't dry, maybe we should keep them from getting wet! Some of those old details will still work for us and some won't. If we are expecting better thermal performance we need to give the walls (and other building parts) better water management so they can make it to the next generation and beyond.
With future posts I'll explore the details, but new construction will have different solutions than rehab, probably. With rehab or retrofit you have to think more carefully about what the strengths and weaknesses of the building are, what the extent of the planned work will be and what can realistically be done within those constraints. The reason I love working with older buildings is that I can use all those lessons I mentioned earlier and, with luck, get some more.
Oh, one more thing. When you do undertake a rehab on an old building remember to leave a penny with the year you completed the work where someone will find it when they get around to their own project in the future. They'll know that you were thinking about them and maybe take the time to learn a few lessons of their own.
Sometimes it's a structural choice; how were two pieces of wood joined, why was that support here and not there. It could be material choice or why did that window go into THAT corner. Sometimes there's a really good, smart reason, other times it's tough to figure and there are some clear mistakes. These are lessons that are sitting right there waiting to be learned and many of them are still applicable today.
One important thing about successful (surviving) old buildings is that they could dry out if they got wet. Quickly too. And that's the important part, if wood stays wet it rots. If it dries quickly it's fairly forgiving of some periodic wetting. If you let it get too wet too often your building won't survive for future generations to see how stupid you were.
How did they dry and are there lessons about that for today? They dried because of lot's of air and energy flow and materials that don't trap moisture. No insulation and free air movement in wall cavities are a recipe for drying. Interior horsehair plaster dries very rapidly which also helped keep the walls dry. Of course in the 18th & 19th centuries showers and hot tubs were in short supply and indoor swimming pools were even rarer. So buildings had lower moisture loads to deal with and had good drying potential. That's a good way to make a building that will last.
We have become more regular in our hygiene and with high energy costs we want insulation in our walls and ceilings. This puts us in a bit of a bind because we just messed up our building longevity strategy. What to do? Let's go back to our original building and see what else we need to change. Well, if the walls won't dry, maybe we should keep them from getting wet! Some of those old details will still work for us and some won't. If we are expecting better thermal performance we need to give the walls (and other building parts) better water management so they can make it to the next generation and beyond.
With future posts I'll explore the details, but new construction will have different solutions than rehab, probably. With rehab or retrofit you have to think more carefully about what the strengths and weaknesses of the building are, what the extent of the planned work will be and what can realistically be done within those constraints. The reason I love working with older buildings is that I can use all those lessons I mentioned earlier and, with luck, get some more.
Oh, one more thing. When you do undertake a rehab on an old building remember to leave a penny with the year you completed the work where someone will find it when they get around to their own project in the future. They'll know that you were thinking about them and maybe take the time to learn a few lessons of their own.